Product Model : | ZCT-IOTH-WL-2x-JLA8 |
Measuring Range : | ±5 ° ( ±30 °) |
Output : | LoRa |
Power: | Voltage(5V) |
Application : | Internet of Things |
IP Degree : | IP67 |
ZCT-IOTH-WL-2x-JLA8 is a LoRaWAN-based inclination sensor developed and produced by Zhichuan Technology (Shanghai) Co., Ltd., with a maximum measurement range of ±30 degrees on both axes. It can be widely used in building construction, geological survey, municipal administration, communications, heat, water, electricity and other industries. Customers can choose from CN470, EU868 and As923 frequency bands, based on their location.
Item | Conditions | Min | Typical | Max | Unit |
Power Source | D-size
ER34615 Lithium Thionyl Chloride battery (1 |
2.7 | 3.6 | 3.8 | VDC |
Quiescent Current (Standby) | Alarm enabled | 210 | 220 | uA | |
Alarm cancelled | 5 | 10 | |||
Peak Current | 300 | 1,000 | mA | ||
Working Temperature | -40 | +85 | °C | ||
Stocking Temperature(2 | Without battery | -40 | +85 | °C | |
With battery (recommended) | +25 | +30 | °C |
Note 1: Lithium ion batteries should never be recharged, otherwise they may explode. When a battery is out of power,
please replace it in time, do not charge it!
Note 2: The self-discharge rate of the battery is less than 3% a year, if it is stocked at room temperature (25°C). The
self-discharge rate becomes higher if the battery is stocked at a higher temperature.
Performance parameters:
Item | Testing Conditions | Min | Typical | Max | Unit |
Measurement Range | two axis | -30 | 30 | ° | |
Resolution(1 | 0.001 | ° | |||
Accuracy | -15 ~ +15°C | ±0.005 | ° | ||
-30 ~ +30°C | ±0.01
or ±0.0167 |
°
% F.S. |
|||
Zero Point Temperature Drift | -40°C ~ +85°C | ±0.001 | °/°C | ||
±0.065 | ° | ||||
Zero Point Deviation | ±0.05 | ° | |||
Heartbeat Interval(2 | 60 | 86,400 (default) | 131,071 | second | |
Alarm Angle | same for X and Y axis | 3 | ° | ||
Alarm Accuracy(3 | -5°~ +5° | ±0.01 | ±0.03 | ° | |
-15°~ +15° | ±0.03 | ±0.1 | ° | ||
-30°~ +30° | ±0.1 | ±0.3 | ° | ||
Alarm Delay Time(4 | 0.3 | 2 (default) | 25.5 | second | |
Battery Working Time(5 | 6 | year | |||
IP level | housed | IP67 |
Note 1: Resolution refers to the minimum variation that can be detected by the sensor while working in its valid range.
Note 2: Heartbeat interval refers to the time interval at which the device periodically uploads data to the server.
Note 3: Alarm accuracy refers to the angular error when the product triggers an alarm. Suppose the alarm angle is 3 degree and the alarm accuracy is 0.03 degree, if X and Y axis angle are smaller than 2.97 degree, alarm will not be triggered, if X or Y axis angle is between 2.97 and 3.03 degree, alarm may or may not be triggered, if X or Y axis angle is larger than 3.03 degree, the alarm will be triggered for sure.
Note 4: Alarm delay time refers to the time when the device continues to tilt beyond the alarm angle to trigger an alarm.
Note 5: Estimation is based on such conditions: at an ambient temperature of 25°C, the capacity of the battery is 19,000mAh, the battery loss factor is 0.7, and the heartbeat rate is 24 hours. Average current for transmitting data ≈ 31mA, time for single transmission ≈ 22s, battery working time = 19000*0.7/24/365/ ((0.22*(24-22/3600)+31*22/3600)/24) ≈ 6 years.