Product Model : | ZCT245J-LCS-E3-145 |
Measuring Range : | ±45 ° |
Output : | CAN |
Power: | Voltage(8~30V) |
Measuring Axis : | Dual Axis |
Accuracy : | 0.1 °-0.5° |
Resolution : | 0.1 ° |
Application : | Machinery |
IP Degree : | IP65 |
Temperature : | -40℃ ~ +85℃ |
Ⅰ. General description
ZCT245J-LCS-E3-145 dual-axis tilt sensor is designed and produced by ZC SENSOR. Measuring range:± 45°, CAN communication.
Ⅱ. Features
Industrial devices entirely
Stable and reliable performance
cast-aluminum housing
with IP65 protection grade
Wide power supply
reverse power protection
Ⅲ. Application
Angle test
Safe control, monitoring, alarm
Standard control, bend control
Tilt attitude recorder
Ⅳ.Technical specification:(unless special mark, the following data are typical value in-room environment 25℃)
Item | Test condition | min. | typ | max | unit | |
Operation
parameter |
Supply voltage | DC | 8 | 12 | 30 | V |
Quiescent current | VCC=12.00V | 50 | 60 | mA | ||
Working temperature | -40 | +85 | ℃ | |||
Performance
parameter |
Test range | Dual-axis | ±45 | degree | ||
resolution(1 | 0.1 | degree | ||||
accuracy(2 | ±0.5 | degree | ||||
repeatability | ±0.2 | degree | ||||
Zero temperature drift(3 | -40— +85℃ | 0.5 | 0.86 | degree | ||
Response time(4 | 100 | ms | ||||
Other
parameter |
Storage temperature | -45 | +125 | ℃ | ||
Protection | IP65 |
Remark 1:
Resolution means the smallest variation of measuring device which can be detected by the sensor during the measuring range.
Remark 2:
Accuracy means the difference between the displayed value of the sensor and the true value.
Remark 3:
zero temperature drift means when the output is 0º under the room environment,
the offset of the angle when change temperature.
Remark 4:
Response time means the required time for sensor output rising to 85% of the output, which is caused by a step change of the measured angle.
Ⅴ. CAN communication protocol
Pls see the product datasheet
Ⅵ. Wire installation and pin definition:
In order to get the biggest range of angle variation, the sensor should be installed horizontally when the carrier or platform is normal.
Wire connection:
PIN1 ―――― NC PIN2 ―――― VCC power supply
PIN3 ―――― GND PIN4 ―――― CAN_H PIN5 ―――― CAN_L
Outside dimension :
Ⅶ. Installation attentions:
Order information:
Optional component-plate: AZB-03;
Countersunk head screw: M4*12;