Welcome to Zhichuan Technology (Shanghai) Co., Ltd.
  • Home
  • Product
  • Inclinometer
  • CANopen 2 axis inclinometer sensor with high precision and stability
  •  » CANopen 2 axis inclinometer sensor with high precision and stability
    CANopen 2 axis inclinometer sensor with high precision and stability
    Product Model : ZCT290K-LCS-H2-77
    Measuring Range : ±60 ° ( ±90 °)
    Output : CAN
    Measuring Axis : Dual Axis
    Accuracy : 0.01°-0.09°
    Application : Machinery
    IP Degree : IP67
    Shell Size : 54 * 44 * 20 mm
    cable_line 3m Waterproof Cable
    GET A PRICE
    Description:

    ZCT290K-LCS is a two-axis inclinometer sensor with high precision and stability. The total range is from -90º to 90º, CAN communication.

     

    .Features:

    High accuracy, high-cost performance,

    Industrial devices entirely, high stability,

    Reliable performance,

    Aluminum casting case,

    Protection grade: IP66

    Wide DC supply, reverse power protection

     

    .Applications:

    Angle measurement

    Security control, monitoring, alarm

    Alignment control, warping control

    Tilt position recorder

     

    . Technical Parameter(unless special mark, the following data are typical value in-room environment(25℃).

    Item Test condition Min

    value

    Typical value Max

    value

    Unit
    Supply voltage DC 8 12 30 V
    Quiescent current VCC=12.00V 21 27 32 mA
    Operating

    temperature

    -40 +85
    Total range Two-axis ±30、±45、±60、±90 º
    Resolution(1 Total range≤±90 0.01、0.05、0.1 º
    Accuracy(2 Total range≤±10 ±0.05 º
    ±10<Total range≤±30 ±0.1 º
    ±30<Total range≤±80 ±0.15 º
    ±80<Total range≤±90 ±2 º
    Repeatability Total range≤±10 ±0.03 º
    ±10<Total range≤±30 ±0.05 º
    ±30<Total range≤±80 ±0.1
    ±80<Total range≤±90 ±1 º
    Zero temperature

    drift(3

    -40—+85℃ 0.005 0.01 °/℃
    Storing temperature -40 +85
    Cable length 2.9 3 3.1 m
    零点 0.2

    Remark 1: Resolution means the least variation of measuring device which can be detected by

    sensor during the measuring range. The resolution is 0.01º in the rang of 90º, and the bigger the

    angle is, the lower the resolution is.

    Remark 2: Accuracy means the difference between displayed value of the sensor and the true

    value.

    Remark 3: zero temperature drift means when the output is 0º under the room environment, the

    offset of the angle when change temperature.

    Remark 4: Sensitivity temperature drift means the sensitivity changes with the change of

    environment temperature. The tolerance on the measuring results is as follow:

    arcsin (sinθ/(1±Δ%))–θ [θ is actual angle,Δ is the offset of the sensitivity]

    Remark 5: response time means the needed time of sensor output reaching 85% of the final output,

    resulted by the step change of measured tilt.

     

    .Installation size and wire connection definition:

    In order to obtain the largest variable range of tilt, when the delivery tools and platform are in a normal

    position, the module should be installed in horizontal.

    Wire connection definition

    White ―――― VCC           Yellow ―――― GND

    Green ―――― CAN-H      Brown ―――― CAN-L

  • OEM & PRICE

    Lowest prices ever, thanks to mass production and integral procurement strategy.

  • TEAM

    Our professional R&D and service engineers can find for you solutions that best suit.

  • ON TIME

    Efficient and effective production management, timely follow-up.

  • QUALITY

    One year warranty, long-time stability and reliability, 100% QC passed before delivery.

  • Top