Product Model : | ZCT260KS-LBS-BUS |
Measuring Range : | ±60 ° |
Output : | RS485 |
Power: | Voltage(8~30V) |
Measuring Axis : | Dual Axis |
Accuracy : | 0.01°-0.09° |
Resolution : | 0.01° |
Application : | Machinery |
IP Degree : | IP65 |
Shell Size : | 54 * 44 * 18 mm |
ZCT260KS-LBS-BUS is a 2-axis high accuracy, quick response, lower zero temperature drift inclinometer which is researched and produced by Shanghai Zhichuan. Its maximum measuring range is +/-60°, RS485 interface, digital angle output.
Features
High accuracy, quick response, high-cost performance Industrial devices entirely, stable and reliable performance.
Applications
Construction machinery, construction
vehicles Security control, tilt control
Angle measurement, level adjustment,
zero position adjustment.
Technical Specification:(unless specifical indification, the following are typical value in room environment(25℃).)
parameter | Test condition | Min value | Typical value | Max value | unit | |
Electrical characteristics
|
Supply voltage | DC | 8 | 12 | 30 | V |
Static operating current | VCC=12.00V | 30 | 40 | mA | ||
Operating temperature | -40 | +85 | ℃ | |||
Performance characteristics
|
Measuring range | Dual axis | ±60 | ° | ||
Resolution(1 | 0.01 | ° | ||||
accuracy(2 | ≤±30 | ±0.05 | ° | |||
≤±45 | ±0.1 | ° | ||||
≤±60 | ±0.15 | ° | ||||
Repeatability
|
±0.03 | ° | ||||
Output frequency | 38400 baud rate | 38 | Hz | |||
zero temperature drift
(3 |
-40— +85℃ | 0.1 | 0.15 | ° | ||
sensitivity temperature drift
(4 |
-40—+85℃ | 0.006 | %/℃ | |||
Others | Storage temperature | -45 | +125 | ℃ | ||
Waterproof grade | IP65 |
Connector definition:
Installation attentions:
Incorrect installment will lead to a big tolerance on the measured angle. Make sure the correct installation of ‘two planes’ and ‘two lines’, please pay attention to the following two points:
①: ‘two planes’ means the mounting surface of the sensor should entirely be close to the mounting surface of the measured objects(the mounting surface of the measured objects should be horizontal as possible as it can). Angle is not allowed(eg: angle a in diagram A). The correct installation method refers to diagram B.
②:‘two lines’ means the axis line should parallel to the axis line of the measured objects. Angle is not allowed(eg: angle b in diagram C). The correct installation method refers to diagram D.